V3 Consulting Engineers (Pty) Ltd invites tenders on behalf of the Applicant, the South African National Roads Agency SOC limited, for the Subservice of managing the environmental process and monitoring environmental compliance during construction for the Upgrading on National Route 1 Section 4 between Doornfontein (KM 63.0) and Laingsburg (KM 81.7). This project is in the province of Western Cape and in the district municipality of Central Karoo at Laingsburg Local Municipality. The approximate programme for design is to be completed by November 2023, followed by construction monitoring of 24 months, commencing October 2024. (Oferta №91337399es)

Registrarse

Compartir:
País: South Africa
Idioma: EN
Número: 91337399
Fecha de publicación: 27-09-2023
Fuente:

Descripción

La información completa sobre la licitación está cerrada.
Para seguir trabajando con el sitio, lea la información a continuación

Acerca de nosotros

Motor de búsqueda líder para licitaciones y compras en Rusia y el mundo

  • La mayor base de datos de licitaciones y fuentes de adquisiciones en Rusia y el mundo
  • Envío diario gratuito según su configuración
  • Información sobre los ganadores de las licitaciones en el formato que necesita
  • Cómoda visualización y carga de información

Elíjanos

Comenzando

Registro en el sitio, después de lo cual las siguientes funciones del sitio estarán disponibles para usted:

  • Suscríbase a listas de correo gratuitas para sus frases clave
  • Ver anuncios de licitación
  • Exportar información resumida en formato Excel
  • Ver parte de la información sobre los ganadores, proveedores y clientes de las licitaciones

Registro

Para utilizar todas las funciones del sitio y ver la información completa, necesita registrar una cuenta comercial

  • Tarifa seleccionada
  • Paga por el acceso de cualquiera de las formas posibles

Acceso completo
Quotations are hereby invited for the following: Supply of batteries, size AAA and AA. Specifications: - AAA x 1200 units; - AA x 1200 units. Required at: RK Khan Hospital. Province: KwaZulu-Natal. Department: Department of Health. Division or section: Central Supply Chain Management. Contract Period: Once off. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Tools & Machinery: • 3 each x Fluke/1507, Specifications: Fluke 1507, Insulation Resistance Tester, measuring range: 0.01Mohms to 10 Giga ohms. Test voltage: 50V, 100V, 250V, 500V, 1000V, • 3 each x FLIR DM166, Imaging TRMS Multi meter, Specifications: IR Resolution: 60 × 80 pixels (4,800 pixels), AC/DC voltage: Range: 600.0 V, Basic Accuracy: ±0.7%±0.5% AC/DC, Amps: Range: 10.00, A Basic Accuracy: ±1.0%/±0.7%, Imaging and optical: Focus: Fixed IR resolution: 60 × 80 pixels (4,800 pixels), Thermal image palettes: Rainbow, iron, grey, scale measurement and analysis AC/DC amps: Range: 10.00, A Basic Accuracy: ±1.0%/±0.7% AC/DC mAmps: 600 mA, Basic Accuracy: ±1.0%/±0.7% AC/DC microAmps: 400µA, Basic Accuracy: ±1.5% AC/DC mVolts: 600 mV, Basic Accuracy: ±1.0%/±0.5%, AC/DC Voltage: 600V, Basic Accuracy: ±0.7%/±0.5%, Capacitance: Range basic accuracy: 200nF ±1.5% 200µF, ±1.5% 2.000mF, ±2.0% 10.00mF, ±5.0%, Continuity check: between 30 and 480, Diode test: Range 3.00V, Basic accuracy ±9.0%, Frequency range: Range: 99.99 kHz, Basic Accuracy: ±1.0% Resistance: Range: Basic Accuracy: 600.0 O ±0.3% 600.0 kO, ±0.5% 6.000 MO ±0.9%, 60.00 MO ±1.5%, Temperature range: 10 to 150°C (14 to 302°F), Measuring rate: 5 samples per second, Thermocouple: 40 to 752.0°F DMM ± (1.0% + 3°F), 40 to 400°C DMM ± (1.0% + 1.5°C), True RMS: Yes VFD AC Voltage: Range: 600.0, V RMS Basic Accuracy: ±1.0%, Power Auto Power Off: yes, Battery: 3 AA batteries; optional TA04 Li-Poly rechargeable battery, Safety Category Rating: CAT III-600V, CAT IV-300V, • 2 each x Fluke TL175, Specifications: Fluke TL175 twist guard test leads, Rating: CAT II 1000V, CAT III 100V, CAT IV 600V,10A max. It comes in set, • 7 each x Electricians tool set, • 4 each x FLIR TA72, Specifications: 10 Inch Universal Flex Current Probe CAT IV 600V,CAT III 1000V, Measurement & Analysis: AC Current, Bandwidth: 45Hz - 500Hz, (sine wave) AC Current Ranges and Resolution: 30.0A, 300.0A, 3000A Basic AC, current accuracy (full scale): ± 3.0% + 5 digits, Flex Coil Diameter: 0.3" (7.5mm), Flex Coil Length: 10" (25 cm), Flex Coil Tip Diameter: 0.5" (13mm). Delivery Date: 2023/11/30. Delivery To: Water Services - E & AM Maintenance Plant. Delivery Address: Trading Services, Ottery. Please note this quotation was published late. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Supply of Cidex OPA solution test strips, Quantity: 02 bottles (60 strips per bottle). Required at: RK Khan Hospital. Province: KwaZulu-Natal. Department: Department of Health. Division or section: Central Supply Chain Management. Contract Period: Once off. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Supply of Spares. Specifications: V Belt, Assembly Cylinder, Hydraulic Motor, Control Lever, Proximity Switch, Roller Bearing. Please note that this quotation was published late. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Fire Extinguishers. Specifications: Request for services of an accredited service provider fighting equipment ide in the firefighting sector to service, repair and replace firefighting equipment (hose reels, Fire Extinguishers, Hydrants and signage) at Northern Services depot (SCM, Roads, Ablutions, Clinic, Scientific Services, Waters Services, Standby Quarters Parks, Building and Structures). NB: The appointed service provider shall submit a soft copy on excel with an inventory of all fire fighting equipment. Fuente: ONLINE TENDERS

Re-Advertisement: Quotations are hereby invited for the following: Supply of micro mist inline nebuliser, Quantity: 04 boxes. Required at: RK Khan Hospital. Province: KwaZulu-Natal. Department: Department of Health. Division or section: Central Supply Chain Management. Contract Period: Once off. Fuente: ONLINE TENDERS