Quotations are hereby invited for the following: Provision of S00 VSD installation for Transnet Soc Ltd operating as Transnet Port Terminals at the Port of Richards Bay. Scope: Supply and install, test and commission 1 x Siemens Sinamics G120 Power Module PM240-2 (380-480V) 75KW High overload, 90KW low overload. Drive to suite a 75-110 Kilowatts, 400v squirrel cage induction motor. NB: The variable speed drive must come in a completely wired standalone panel with all the required protections. (Oferta №83835398es)

Registrarse

Compartir:
País: South Africa
Idioma: EN
Número: 83835398
Fecha de publicación: 10-05-2023
Fuente:

Descripción

La información completa sobre la licitación está cerrada.
Para seguir trabajando con el sitio, lea la información a continuación

Acerca de nosotros

Motor de búsqueda líder para licitaciones y compras en Rusia y el mundo

  • La mayor base de datos de licitaciones y fuentes de adquisiciones en Rusia y el mundo
  • Envío diario gratuito según su configuración
  • Información sobre los ganadores de las licitaciones en el formato que necesita
  • Cómoda visualización y carga de información

Elíjanos

Comenzando

Registro en el sitio, después de lo cual las siguientes funciones del sitio estarán disponibles para usted:

  • Suscríbase a listas de correo gratuitas para sus frases clave
  • Ver anuncios de licitación
  • Exportar información resumida en formato Excel
  • Ver parte de la información sobre los ganadores, proveedores y clientes de las licitaciones

Registro

Para utilizar todas las funciones del sitio y ver la información completa, necesita registrar una cuenta comercial

  • Tarifa seleccionada
  • Paga por el acceso de cualquiera de las formas posibles

Acceso completo
Quotations are hereby invited for the following: Supply and deliver black refuse bag. Scope: - Bag 40 micron Refuse 760 x 910, (Black); - All bags must be printed uMH; - Packed in bales of 250. Qty: 50 000. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Provision for refurbishment of Mafi Haulers for Transnet Soc Ltd operating as Transnet Port Terminals. Scope: - The works that the contractor is to perform pertains to the structural maintenance, corrosion removal and painting of five (5) Mafi Haulers located at Transnet Port Terminals, Pier 2 Container Terminal in the port of Durban; - The purpose of the maintenance intervention is to preserve the asset and increase its useful lifespan; - The works to be executed on these Hauler"s is concentrated mainly on and around the H-Frame channels, cabin arrangement (interior, exterior, roof and guards), handrails, access staircases, fifth wheel, guard plates and side mirror mounting brackets; - The objective for this works is to ensure that the structural integrity of these Haulers remain intact; - The works needs to be planned and executed by employing a quality system methodology; - The Contractor must provide all the necessary resources such as skills, materials, tools, equipment, and labor as required to perform the works. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Supply and delivery of Electrical Items. Scope: - Fitting Streetlight 55 w LED, Qty: 60. - Transparent and weather resistant grade polycarbonate optical cover - service lifetime - 100000 hours, suitable to operate at minus 40 degrees Celsius to 50 degrees Celsius ambient temperature. LED fitting 6500 effective (output) luminous flux, min 130 lm per watt fitting, Driving current maximum of 700mA. IP66 impact resistance IK08 min, high pressure die/cast aluminium housing LM6. Surge protection 15-20KV/kA. Power factor of 0.95; - 55w or less. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Provision of service & repair charger 2 piston stops for Transnet Soc Ltd operating as Transnet Port Terminals at the Port of Richards Bay. Scope: The service provider should do the following: 1. Collect two Pistons Stops at a time, only collect the balance once the first two is serviced/repaired and reinstalled onsite; 2. Clean piston stops; 3. Drain all oils; 4. Drain all nitrogen from accumulators; 5. Strip all valves from the manifold; 6. Clean manifold and clean all valves; 7. Perform leakage test on valves to determine the functionality. Replace if not functional; 8. Test Pressure gauge; 9. Strip cylinder completely and clean all parts; 10. Measure up all parts and tolerances to OEM drawings; 11. Replace wear strips if it is the new design only; 12. Strip chrome and replace the chrome on the piston stop rod; 13. If the design is old, change the old design to the new design which includes the wear strips; 14. Replace all seals; 15. Replace top cap and wear ring if found not useable; 16. Redrill and tap the mounting holes for easy installation; 17. Clean up all mounting and attachment holes; 18. Supply new mounting bolts grade 10.9; 19. Assemble piston stop; 20. Mount the cleaned manifold and valves onto the piston stop; 21. Fill with new oil; 22. Pre charge accumulator; 23. Test the piston stop in a simulation test bench; 24. Set pressure relief valve to design specification; 25. Paint and package piston stop; 26. Test the machine and hand over. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Supply and deliver recycling bin 240l. Qty: 200. Fuente: ONLINE TENDERS

Quotations are hereby invited for the following: Provision of workshop gantry crane fabrication and installation for Transnet Soc Ltd operating as Transnet Port Terminals at the Port of Richards Bay. Fuente: ONLINE TENDERS